Exempting Pumps with Dual Mechanical Seals from Method 21

Published: 2026-11-17      Revised: ---

Some regulations exempt pumps with dual mechanical seals (DMS) from routine Method 21 monitoring. In Chateau, whether a component is scheduled for Method 21 comes from its rule. To stop scheduling qualifying pumps, give them their own SubType or SubSubType, then set that SubType or SubSubType to Exempt in the rule.

How it works​

Chateau doesn't decide on its own that a pump is exempt. The rule assigned to the pump sets its monitoring frequency by component type. If a DMS pump keeps showing up on the Schedule or in tours, its rule is still giving its type a monitoring frequency.

Setting your DMS pumps up as their own SubType or SubSubType lets the rule treat them separately from pumps that still need monitoring.

  • SubType: use this if your pumps don't already use SubTypes you need to keep (for example, Pump > Dual Mechanical Seal).
  • SubSubType: use this if your pumps already have SubTypes you report on, such as Centrifugal. Add DMS one level down (for example, Pump > Centrifugal > Dual Mechanical Seal) so you keep the existing SubType.

Note: Don't mark DMS pumps as Sealless. Pumps with dual mechanical seals have seals and fall under a different exemption.

Steps​

  1. Add the SubType or SubSubType. Go to Settings > Picklists and add a Dual Mechanical Seal SubType or SubSubType under Pump. You need the Settings and Resource Management role to do this. If you don't have it, ask your Chateau administrator or submit a ticket through the help desk.
  2. Update your DMS pumps. In the Components grid, select the qualifying pumps and use Multi-Edit to set the new SubType or SubSubType. You need the Processor role to make component changes. If you aren't also an Approver, the changes go to the MOC porch for approval first.
  3. Copy the rule. You need the Rules Management role to edit rules. Go to Rules > Create and Select Rules. Rules that have already run can't be edited, so select the rule in Applied Rules and click Copy and Edit Selected Rule. (If the rule hasn't run yet, you can use Edit Selected Rule instead.)
  4. Set the frequency. In Manage Rule Specs, select the rule. In M21 Frequency, add a row for the DMS pump SubType or SubSubType and set the frequency to Exempt.
  5. Replace the old rule. Follow the steps in Create and Select Rules so the new copy replaces the old rule for these components.
  6. Save your changes. The rule runs overnight (4:00 AM by default), and the exempt pumps stop appearing on the Schedule after it runs.

Before you change the rule​

  • Check the regulation's conditions. A dual mechanical seal exemption usually has conditions, such as a barrier fluid system, a sensor that detects seal failure, and regular visual checks. Chateau doesn't check whether a pump meets these conditions. You're responsible for confirming each exempt pump qualifies, and for any other inspections the regulation still requires.
  • Initial monitoring. Pumps with an Exempt frequency are also exempt from initial monitoring, unless Exempt Require Initial is turned on in the rule's Initial settings.
  • Timing and built tours. Exempt pumps that are already on a built tour drop off that tour once the rule runs, so try to make the change when no tours are built. See Timing Rule Updates.
  • Need help? If you'd rather not edit the rule yourself, submit a ticket through the help desk. We can update the rule specs for you after you approve them. If you can't reach the help desk, email support@ldartools.com.