Delete an Inspection and Delete a Repair Attempt
Published: 2022-07-26 Revised: 2026-11-10
Deleting an inspection and deleting a repair attempt are controlled by the Delete Inspections and Repair Attempts role. See Change User's Roles for a Database on how to edit user roles.
Button greyed out? If Delete Inspection or Delete Attempt stays inactive even though you have the role, see Why the Delete Inspection Button Is Greyed Out (and Who Can Edit Inspection Times).
Delete an inspection
-
Open the Inspections grid on the Inspections & Attempts tab.
-
Query the grid.
-
Select the inspection you want to delete.
-
Click Delete Inspection at the top of the grid.
Note: Only one inspection can be deleted at a time.
-
Enter the reason you're deleting the inspection in the text box.
-
Click Delete.
Need to delete a lot of inspections?
If a large group of inspections needs to be removed (for example, a full day of monitoring entered by mistake or done without a valid calibration), contact LDARtools support instead of deleting them one at a time. Include:
- The database
- The date or date range, and the time range if only part of a day is affected
- The technician
- The analyzer
- The reason the inspections are being deleted
Support will remove the inspections and let you know when it's done. Just like a single deletion, the inspection requirements those inspections satisfied return to the schedule, or are reported as missed inspections if no later inspection satisfies them.
OGI and Cooling Tower inspections are deleted the same way from the OGI Inspections and Cooling Tower Inspections grids.
Deleting an inspection deletes any AVO events and leaks created because of that inspection. It also unsatisfies any inspection requirements that inspection satisfied.
The inspection requirement then returns to the schedule, or is reported as a missed inspection if no future inspection satisfies it. Chateau also reruns the rules on all inspections of that component that occurred after the deleted inspection, so it can satisfy any inspection requirements or open a new leak if needed.
When the inspection is involved in a leak
When you delete an inspection that is involved in one or more leaks, the delete dialog lists those leaks before you confirm, so you can see the impact first. They're grouped as Opened by this inspection or Occurred during this leak, and each entry links to that leak's details.
If the inspection opened a leak, the dialog warns that deleting the inspection will also permanently remove that leak record. You must enter a reason before the delete is allowed.
This warning appears when deleting from the Inspections, OGI Inspections, and Cooling Tower Inspections grids. Deleting a repair attempt doesn't show the leak warning.
Delete a repair attempt
-
Open the Attempts grid on the Inspections & Attempts tab.
-
Query the grid.
-
Select the attempt you want to delete.
-
Click Delete Attempt at the top of the grid.
Note: Only one attempt can be deleted at a time.
-
Enter the reason you're deleting the attempt in the text box.
-
Click Delete.
Inspection logged on the wrong tag
If an inspection was logged on the wrong component, you have two options:
- Edit the inspection and move it to the correct tag. See Editing an Inspection.
- Delete the inspection and re-enter it manually on the correct tag. Deleting requires the Delete Inspections and Repair Attempts role.
Either way, Chateau reruns the rules for the inspection, so check the leaks on both tags afterward.
Deleting in Chateau Mobile
You can also delete inspections in Chateau Mobile. See Deleting an Inspection in Chateau Mobile for that procedure.
Tip: Turn on the Deleted Inspections porch to keep a list of these deletions, so you can give feedback to technicians and users whenever one happens.