Skip to main content

Why the Delete Inspection Button Is Greyed Out (and Who Can Edit Inspection Times)

Published: 2026-11-05      Revised: ---

To delete an inspection or a repair attempt in Chateau, you need the Delete Inspections and Repair Attempts role. But the Delete Inspection button can still be greyed out even when you have that role. This article explains why, and how to fix it. It also covers who can change an inspection's date and time.

Check the tooltip first​

Hover over the greyed-out Delete Inspection button.

  • If a tooltip says "You must have the 'Delete Inspections and Repair Attempts' role to perform this action", Chateau doesn't see the role for you on this database. Go to Chateau doesn't see your role.
  • If there's no tooltip, you have the role. The button is waiting on your selection. Go to Check your selection.

Chateau doesn't see your role​

The role is on a different database​

Roles are assigned per database. Having the role on one database doesn't give it to you on another. Check that your Chateau Administrator assigned the role on the database you're signed in to.

The role was just added​

Chateau reads your roles when you sign in, and refreshes them about every 15 minutes. If the role was added while you were signed in, the button may stay greyed out until then.

To pick up the new role right away, sign out of Chateau and sign back in.

The role was never assigned​

Ask your Chateau Administrator to add Delete Inspections and Repair Attempts to your user, or to a security group you belong to, on this database. See Change User's Roles for a Database.

Note: This role is kept separate from the other roles on purpose, because a deletion can't be undone. Having Leaks/DOR Management, Administrator, or other roles doesn't include it.

Check your selection​

When you have the role, Delete Inspection (and Delete Attempt) is active only when:

  • Exactly one row is selected. The button stays greyed out with no rows selected, or with two or more. You can delete only one inspection at a time.
  • The grid has finished loading. The button is inactive while a search or a delete is still running.

Make sure you're on the right grid​

The delete buttons are only on these grids under Inspections & Attempts:

To deleteUse this gridButton
M21 or AVO inspectionInspectionsDelete Inspection
OGI inspectionOGI InspectionsDelete Inspection
Cooling Tower inspectionCooling Tower InspectionsDelete Inspection
Repair attemptAttemptsDelete Attempt

There's no delete button on an inspection's details screen or in Tag View. Find the inspection in the grid above, select it, and delete it from there. For the full steps, see Delete an Inspection and Delete a Repair Attempt.

Who can edit an inspection's date and time​

No special role is needed. Any user who can sign in to the database can edit an inspection's or repair attempt's date and time.

To change one inspection:

  1. Go to Inspections & Attempts and find the inspection.
  2. Double-click it, then click Edit.
  3. Change Performed On.
  4. Click Save.

Repair attempts work the same way from the Attempts grid.

To shift the time on a group of inspections, use Multi-Edit. See Editing the Inspection Time on a Group of Inspections.

Keep in mind:

  • The date can't be earlier than the date the component was added, and it can't be in the future for the facility's time zone.
  • Changing the date reruns the rules on the inspection. Any leaks it opened are removed and reopened from the new date, so repair deadlines can change. See Editing an Inspection.

Note: OGI sensitivity checks are different. Editing a recorded sensitivity check, including its timestamp, needs the Edit Sensitivity Checks role.